Do you need to speak to our experts?
This form is protected by reCAPTCHA - the Google Privacy Policy and Terms of Service apply.
Power distribution units (PDUs) share mains power between servers, switches and other equipment in a rack, on a bench or at a desk. The main choice is the input, whether a 13A UK plug, a C14 or 16A C20 IEC inlet, or a 16A or 32A commando plug. After that, choose the socket type and how many ways you need.
Shop by type
A PDU with a UK plug is limited by its 13A fuse, so it suits small racks and home or office cabinets. A C14 inlet connects to a UPS or another PDU's C13 outlet and is rated at 10A. For heavier loads, choose a 16A PDU with a C20 inlet or a 16A commando plug, or a 32A commando PDU where a dedicated industrial supply is available. However many sockets a unit has, the total connected load must stay within its input rating.
Pick the outlets your equipment uses. UK sockets suit plug-in adaptors and chargers, C13 suits most servers, switches and monitors, and C19 suits high-draw servers and UPS units. Schuko versions are available for European equipment. Units run from 4 way to 16 way, and combo models mix UK with C13 or C19 with C13 outlets. Horizontal 19 inch PDUs fit across the rack, vertical units mount at the rear, and 10 inch models suit small SOHO cabinets.
Surged models add protection against mains spikes for sensitive equipment. Lead lengths of 1.8m, 3m and 5m let you reach a wall socket or UPS without an extension. Around a UPS, C14 to UK socket splitter leads in 1, 2, 4 and 6 way versions are a simple alternative to a full PDU, and C19 to C20 extension cables lengthen 16A connections. For desks and benches, desktop PDUs combine UK sockets with USB, RJ45 or wireless charging.
A 16A PDU takes power through a C20 IEC inlet or a blue 16A commando plug rather than a 13A UK plug, so it can handle a higher total load. The C20 versions connect to a UPS or upstream PDU with a C19 outlet.
Yes. PDUs with a C14 plug connect to a C13 outlet on a UPS, and C20 models connect to a C19 outlet. Check that the UPS output rating covers everything you plug in.
Horizontal 19 inch PDUs mount across the front or rear of the rack. Vertical PDUs mount upright at the back of the cabinet and suit higher socket counts without taking up rack space.
Yes. Small PDUs start at 4 way with UK sockets and a UK plug, in 1.8m and 3m leads. Many 6 way models are available with UK, C13 or Schuko sockets.
The PDUs in this category distribute AC mains power. They are not designed for 12V DC systems.
Do you need to speak to our experts?
This form is protected by reCAPTCHA - the Google Privacy Policy and Terms of Service apply.